Français Русский Español Deutsch Bahasa Indonesia Tiếng Việt 한국어 ภาษาไทย हिन्दी العربية Português 日本語 English 中文
Determination of fluorine and chlorine in coal2026-03-19  view:61

1.Test procedures

Weigh approximately 0.2g of quartz sand at the bottom of the crucible, place about 0.03g of coal sample on top of the quartz sand, cover the coal sample with a thin layer of quartz sand, perform the test according to the set testing procedure, and calculate the results.

 

2.Combustion conditions

Temperature: 1150℃                 Oxygen: 0.4L/min             

Argon(carrier): 0.2L/min             Argon flow for humidification: 0.1L/min          

Water vapor: 0.1L/min               Absorption solution: pure water


Instrument:SDXNS200H

Combustion process

Step

Sample Introduction Time (s)

Distance (mm)

Retention Time (s)

Step 1

17

200

100

Step 1

100

30

100

Step 3

100

20

100

Step 4

30

70

350

 

3.IC conditions

Analytical Column: SH-AP-1 4*200mm         Guard Column: SH-GP-2 4.0*50mm

Eluent: EGC KOH, 13mM, 0.7mL/min           Column temp.: 35

Quantitative loop: 1000ul                               Linear range:0.1-10mg/L

Detector: SHD-3/6

 

4.Test results

 

 

Interest

GBW11121a

GBW11122a

Measured(mg/kg)

Certified(mg/kg)

Measured(mg/kg)

Certified(mg/kg)

F

245

247±15

1166

1163±36

242

1162

251

1147

252

1167

247

1172

248

1162

Aver.

247.50

1162.67

RSD(%)

1.51

0.73

 

 

 

Interest

GBW11118a

GBW11120a

Measured(mg/kg)

Certified(mg/kg)

Measured(mg/kg)

Certified(mg/kg)

Cl

98

110±20

1090

1110±60

99

1112

103

1099

99

1119

98

1110

101

1117

Aver.

99.67

1107.83

RSD(%)

1.97

1.01

 

Sales Contact
tel 0086 731 88112150
fax 0086 731 88134650
email sales@sandegroup.com
Service Contact
tel 0086 731 89864000
fax 0086 731 88134650
email service@sandegroup.com
Copyright©HunanSundy Science and Technology Co., Ltd.